Our Equipment Units

GASTEC PLUNGER PUMP & ANALYZER TUBE

SPECIFICATION :

  • Case            :  Chromed Stainless Steel
  • Dimensions :  4.75” x 2.75” x 1.65” ( 200 mm x 50 mm x 42 mm)
  • Weight         :  230 Grams
  • Strokes        :  100 ml (Full-stroke); 50 ml (Half-stroke)
  • Diameter     :  36 mm; length : 104 mm









 
3-STAGE ELECTRIC BREATHING AIR COMPRESSOR
( Komba MCH 16/ET)

SPECIFICATION :

  • Capacity      : 260 ltr/minute, 16M3/hr (+/- 9.2 Scfm)  
  • Max. working pressure : 95/38/14 mm
  • Speed of rotation : 1550 rpm
  • Piston stroke : 40 mm
  • Intermediate pressure :
    1st stage 5bar/70 psig
    2nd stage 40 bar/570 psig
    3rd stage 225 bar/3200 psig
  • Power motor : Honda diesel 6.6KW - 9 Hp
  • Dimensions :  1105 x 490 x 650 mm ( L x W x H)
  • Weight         :  148 Kgs
  • Level of acoustic pressure :  dB (A) 95.6 (at the operator's work place)
  • Level of acoustic power  :  dB(A) 109
 

3-STAGE DIESEL BREATHING AIR COMPRESSOR
Komba MCH 16/DH

SPECIFICATION :

  • Capacity      : 260 ltr/minute, 16M3/hr (+/- 9.2 Scfm)  
  • Max. working pressure : 95/38/14 mm
  • Speed of rotation : 1550 rpm
  • Piston stroke : 40 mm
  • Intermediate pressure :
    1st stage 5bar/70 psig
    2nd stage 40 bar/570 psig
    3rd stage 225 bar/3200 psig
  • Power motor : Honda diesel 6.6KW - 9 Hp
  • Dimensions :  1105 x 490 x 650 mm ( L x W x H)
  • Weight         :  148 Kgs
  • Level of acoustic pressure :  dB (A) 95.6 (at the operator's work place)
  • Level of acoustic power  :  dB(A) 109
 

Air Pak Scott Fifty-I SCBA

SPECIFICATION :

  • NIOSH 42 CFR Certified
  • Respiratory Protection for first responders, municipal and industrial firefighters
  • Time-tested record of reliable performance and rugged
  •  Redundant safeguards promote and added margin of safety
  • Includes Sco's workhorse E-Z flow regulator
  •  2216 psi operang pressure
  •  45 cu w/ 30 minutes duraon
  •  Cylinder duraon 30 minutes (Carbon Cylinder)
  •  AV - 2000 face piece allows for interface with Scott's full range of communication devices
    • Schrader Extended Duration Hose for airline connection
 

5 SKA-PAK,Work Unit

SPECIFICATION :

  • Cylinder and Valve Assembly

Construction : Aluminum alloy

Diameter : 4.4 inches (111.8 mm )
Length : 12.4 inches ( 315 mm )
Water Capasity : 80 Cu.in ( 1.3 liters )
Air Capacity : 7 Cu.ft ( 198.2 liters ) at 2216 psig
Rated duration : 5 minutes at 2216 psig ( 152.8 Mpa ) 20F (- 7 C)

  • Regulator E-Z Flow

Facepiece Mounted
Small Diameter
Maintains a positive pressure at high work rates

  • Facepieces  AV 2000
  • Harnesses : Kevlar
  • Airline Connection

Easy entry/egress capability
Preserves Self Contained air supply
Used with up to 300 feet of airline
Operates from 60 – 125 psig
Rectus fittings

  • Weight : 8.4 lbs ( 3.9 Kg )
  • Box Dimension : 370 X 345 X 220 mm ( L X H X W )


Construction   : Stainless steel

APPOVAL NIOSH-MSHA No. TC-13F-68

 

EEBD Solas 15 Minutes (Emergency Escape Breathing Devices) 

THRS-15

Comply with SOLAS 1974, as amended use for people when emergency escape, it is a high performance personal respiratory protective equipment to protect them

Working principle : Reduce the high pressure gas to medium pressure gas into 0.6-0.9 Mpa in the cylinder, flow to hood for human respiratory.


  • Used for emergency escape from any confined spaces
  • Fast air supply system
  • Compressed breathing air technology
  • Easy to refill cylinder, no adaptor required


Cylinder Valve

Thread Spesification : M19x1.5

Pressure Gauge L 0-30Mpa


 

10 SCOTT ELSA ESCAPE DEVICE

SPECIFICATION :

  • Easy to don.
  • Easy to activate. 
  • One size fits all.
  • Secure seal. 
  • Positive pressure air flow 
  • 360 degree visibility
  • Weight (filled): 9.9 lbs. (4.5 kg)
  • Cylinder: 3000 psi aluminum 
  • Flow: 40 lpm


In hazardous or IDLH environments, ELSA provides 5, 10 or 15 minutes of constant flow emergency air at 40 lpm. When the user’s breathing rate may be dramatically increased due to stress or exertion, as in situations where the user must run up stairs to reach safety, the ELSA High Flow EEBD may be a more appropriate choice. This unit forces approximately 75 liters of air per minute into the hood, and provides greater comfort and easier breathing for high exertion escapes. Based on orderly egress at 4 mph, a five-minute ELSA unit allows an individual to travel 1,760 feet. A ten-minute unit allows 3,520 feet. A fifteen-minute unit allows 5,280 feet.

 

WINDSHOCK

SPECIFICATION :

  • Wind Socks Flag
    Material : Made from internaonal Yellow/Orange Nylon with water repellant.
    Dimension : Diameter = 16 inches; length = 60 inches
  • Wind Socks Frame
    Material : Frames are an all steel construction and these are manufactured With ease of installation in mind
  • Wind Socks Rotating Pole
    Material : All steel construction and feature a double ball bearing design
    Dimension : 20 inches length; 2 inches diameter of ball bearing
  • Wind Socks Pole
    Material : 1 inches pipe collar
 

BUG BLOWER

MANCOOLERS

 Standard “T” base mounting, this low noise level, heavy duty units provide man cooling and process cooling for both open work areas and spot cooling. Their rugged construction equals that of a permanent fan, yet can be easily positioned and adjusted for directional floe. In accordance with OSHA and AMCA standards.


SPECIFICATION :

  • Voltage : 3 Phase, 220/480 Volt, 60hz
  • RPM : 1140 rpm; 5,5 HP
  • Blade : 36 Inches
  • Flow Capacity : 20,000 CFM


 

Warning Sign Equipment

SPECIFICATION :

  • Made From : 2.0 mm Aluminium plate.









 

FIRST AID KIT

  • Standard Emergency First Aid Kit
  • Stop Bleeding Medicine
  • Emergency Eye Wash Liquid
  • 4 Surgifix, wrist, arm & elbow
  • 2 Surgifix, leg, foot & shoulder
  • 2 Surgifix, hip, thigh & axilla
  • 4 Singlefix finger bandages
  • 4 Triangular bandages
  • 2 Crepe Bandages 2” & 1 3”
  • 1 Adhesive plaster ½” & 1 rollx1”
  • 4 packs First aid dressings 10’s
  • 1 Water-Jet burn dressing
  • 2 packs of absorbent gauze 20’s & 2 packs x m
  • 2 Ansepc loon & 1 Ansepc cream
  • 1 Iodine solution BP & 1 A Solution 1 : 1000
  • 2 Sodium Bicarbonate powder BP & 1 Eye lotion
  • 24 Coon wool & 1 Constricve bandage
  • 24 Bunches of safety pins & 1 Kidney dish
  • 1 prof Dressing scissors & 1 pr of Dressing forceps
  • 1 Emergency eye wash bole
  • 1 unit “First Aid Airway”
  • 1 “First Aid at Work
 

Yellow Junkin Gall Basket Stretcher

  • Stainless Steel Frame
  • Foot Safety Holder
  • 5 Chan Harness
  • Dimension : 84 1/2" L; 24" W; 7 1/2"



 

TYPE 3150BEP-FM ¾” flange Mount 12 – 74 VDC
Class I Group C & D (gas hazards)
Class II Group E, F & G (dust hazards)

SPECIFICATION :

  • Lamp Type : 700-R1-YELLOW Xenon Strobe Lamp Assembly
  • Voltage and Amperage : 12-74 VDC Draws 1.25 A avg.@ 12 VDC tapering to
    0.2 A avg. @ 74 VDC
  • Power Supply Output :
    13 Watts Standart, 11 Watts for 3150
    9 Joules per Flash Std, 8 Joules per flash for 3150
  • Temperature Range : -40 0c to +55 0C
  • Flash Rate : 85 Flashes per Minute
  • Temperature Code : T6-Class I Groups C & D
  • Intensity :
    Yelow 200 Candela elf
    AMBER 170 Candela elf

 

Air Manifold - 6 connector,
- Max. WP 300 Psi

SPECIFICATION :

  • Maximum working pressure : 300 Psi
  • Coplin : : Broze RECTUS 1/4” Quick Coupling









 

E-Z Radiocom ™ II Communication System


  • Combined voice amplification and 2-way radio interface
  • Clear, crisp voice transmission and recepon
  • Voice amplifier may be used independently by uncoupling quick-disconnect to radio interface cable
  • 3 AAA baeries for voice amplifier provide 22-hour service life (+/-10%) based on 50% duty cycle
  • Large-surface, chest-mounted push-to-talk buon for quick, easy access
  • Available with connectors for most popular 2-way radios
  • Maintains respirator NIOSH cerfication
  • NFPA 1981 compliant as an SCBA accessory
  • Intrinsic Safety Class I, II, III, Div. I, Groups A, B, C, D, E, F, and G per ANSI/UL 913
 

Full Body Harness

  • Kevlar
  • Nylon material
  • Rescuer
















 

H2S CALIBRATION KIT

SPECIFICATION

  • Maximum working pressure : 500 Psi
  • Concentration : 25 Ppm
  • Regulator Flow rate : 0.5 l/min








 

NON EXPLOSION PROOF STROBE LIGHT

SPECIFICATION
Class II Group E, F & G (dust hazards)

  • Lamp Type : YELLOW Xenon Strobe Lamp Assembly
  • Voltage and Amperage :
    12-24 VDC Draws 1.25 A avg.@ 12 VDC tapering to 0.2 A avg. @ 24 VDC
  • Power Supply Output : 13 Watts Standart, 11 Was for 3150
    9 Joules per Flash Std, 8 Joules per flash for 3150
  • Temperature Range : -40 0c to +55 0C
  • Flash Rate : 85 Flashes per Minute
  • Temperature Code : T6-Class I Groups C & D
  • Intensity : Yelow 200 Candela elf
    AMBER 170 Candela elf
 

TOMAR EXPLOSION PROOF FIXED WARNING ALARM SYSTEM

Model 1002wep
Features:

  • Wide Angle Sound dispersion Pattern
  • Explosion proof and Weather Proof For Indoor and Outdoor use
  • Built-in 24 Watt driver
  • Polarity protected (dc unit)
  • Alumunium and Fiberglass Housing
  • Reflex Projector for maximum efficiency
  • Omni-directional mounting bracket
  • Class I, Groups C and D; Gas Atmospheres (Incl. Ethyl, Ether, Gasoline, Naphta, Alcohols, Butane,
    Propane)
  • Class II, Groups E, F and G; Dust Atmospheres (Incl. Metal, Carbon, Grain)


SPECIFICATION :

  • Power : 24 Watts
  • Frequency : 250 – 12,000 Hz
  • Voltage : 12 – 30 Vdc
  • Sound Level Output : 110 dB on axis at 10 Feet
  • Dispersion : 120o X 60o
  • Impedance : 16 Ohm
  • Dimensions : 14”W x 6”H x 17.5”L
  • Conduit Connection : 0.5” rigid pipe conduit
  • Weight : 23 lbs
  • Conduit cycle : Connuous/YELP
 

TOA NON EXPLOSION PROOF SIREN


SPECIFICATION

Class II Group E, F & G (dust hazards)

  • Rated Input Selection/Impedance : ZH-615S: 15W (8 Ω)/ZH-615SM: 15W, 10W, 5W, 2W (100V Line)
  • Frequency Response : 330 ~ 10,511 Hz
  • Sound Pressure Level (1W/1m) : 109dB
  • Dimensions (WxHxD) : 222 x 162 x 234 mm
  • Weight : 1.1 kg (ZH-615S)/ 1.3 kg (ZH-615SM)
  • Material : Horn Flare; Aluminum/ Horn Inner & Cover; ABS Resin
    / Brackets; Steel/Bracket Holder; Aluminum Die Cast
  • Color : Horn (Flare, Inner) & Bracket Holder, Off White,
    Bracket: Dark Gray
 

Air Manifold - 6 connector,
- Max. WP 300 Psi

SPECIFICATION :

  • Capacity : 10 X 47,3 Ltr Breathing air
  • Max. working pressure : 2225 Psi
  • Cylinder diameter : 250 mm
  • Dimension : 930 X 670 X 1900 mm ( L X W X H )
  • Weight :148 kg
  • TP : 300 bar
  • WP : 220 bar
 

4800 Controller

The 4800 Controller from Industrial Scientific is an 8 - 48 analog input controller. With its optional onboard relays, the 4800 can control alarms, fans, horns, etc., when alarm conditions are reached. Being fully programmable, relays can be set to activate from multiple channels, or multiple relays can be programmed to a single channel. Time delays can also be programmed for each relay. This allows the relays to activate after alarm conditions are met for specified periods, or de-activate after a specified time prior to an alarm. 


Along with monitoring analog signals, the 4800 Controller can also monitor up to 72 digital Modbus RTU inputs. The 4800 can be set up as a Modbus RTU master unit to monitor these channels, or it can be set up as a Modbus RTU slave device. As a Modbus RTU slave device, the 4800 Controller can communicate to SCADA, HMI, and PLC controlled systems. 


With a telephone line interface, the 4800 Controller has remote call out capabilities. This allows the controller to phone, fax, or page alarm notifications to users. Phone lists are user programmable and can be entered in a priority. The 4800 can also be remotely programmed via the telephone. 


To keep track of events, the 4800 Controller has a built in event log. The event log will store 1,000 events. Events consist of calibrations, peaks, and alarms. The event log can be viewed via a local printer connected to the 4800 Controller, or through a PC.

SPECIFICATION :

  • ENCLOSURE: NEMA 4X ABS plastic enclosure 
  • ANALOG INPUTS: 8-48 analog inputs (8 per card): 4-20 mA, 0-20 mA, 0-1V, 0-5V, 0-10V, +/-1V, +/-5V, +/-10V
  • DIGITAL INPUTS: 0-72 digital Modbus RTU inputs 
  • OUTPUTS: Fully programmable relay outputs (4 per card) 
  • DISPLAY: LCD display for programming and viewing channel information. Tri-color LEDs for each analog input and relay output to show status of channel. 
  • ALARM NOTIFICATION: LCD alarm notification, LED alarm notification, audible alarm notification via local speaker, telephone dial out notification.
  • PROGRAMMING INTERFACE: Local keypad or remotely via telephone 
  • EVENT LOG: Stores 1,000 entries. Entries include entering and leaving alarm states, peak readings and calibrations.
  • TEMPERATURE RANGE: -40oF to +185oF (-40oC to +80oC) 
  • OPERATING POWER RANGE: 100-240 VAC, 15-18 VDC, on board battery backup.
 

iTrans™ fixed-point gas monitors

Next generation iTrans™ fixed-point gas monitors employ an intelligent electronics platform to provide 1 or 2 points of detection from a single head for maximum flexibility, superior performance and lower installation costs. The three or four wire system is capable of accommodating more than 200 transmitters in an RS485 bus configuration. Able to monitor any combination of gases for a specific environment, iTrans™ utilizes our industry-proven “smart” sensor technology and safety features including automatic sensor recognition, access code security, and zero and cal fault protection – all enclosed within an explosion-proof aluminum or stainless steel housing. 


SPECIFICATION :

  • ENCLOSURES: Cast aluminum, poly-bonded coating or 316 stainless steel. Both are explosion-proof, NEMA 4X, IP66 rated 
  • SENSORS: Combustible Gases: Catalytic bead and/or Non-Dispersive Infrared (NDIR) Oxygen / Toxic Gases: Electrochemical diffusion 
  • MEASURING RANGES: Combustible gases: 0-100% LEL in 1% increments Oxygen: 0-30% by volume in 0.1% increments Ammonia: 0-200 ppm in 1 ppm increments Carbon Monoxide: 0-999 ppm in 1 ppm increments Hydrogen Sulfide: 0-500 ppm in 1 ppm increments Sulfur Dioxide: 0.2-99.9 ppm in 0.1 ppm increments Hydrogen Cyanide: 0.2-30 ppm in 0.1 ppm increments Hydrogen Chloride: 0.2-30 ppm in 0.1 ppm incr. Phosphine: 0-1 ppm in 0.01 ppm increments Nitrogen Dioxide: 0.2-99.9 ppm in 0.1 ppm increments Nitric Oxide: 0-99.9 ppm in 0.1 ppm increments Chlorine: 0.2-99.9 ppm in 0.1 ppm increments Chlorine Dioxide: 0.02-2 ppm in 0.01 ppm incr. Hydrogen: 0-999 ppm in 1 ppm increments 
  • INPUT CURRENT (max): Toxic Gas / Oxygen: 150 mA @ 24 VDC (single gas) Combustible gases (Catalytic): 175 mA @ 24 VDC, 0.6 A peak (single gas) Combustible gases (Infrared): 150 mA @ 24 VDC, 0.6 A peak (single gas) Combined catalytic/infrared: 280 mA @ 24 VDC (two gas)
  • INPUT VOLTAGE: 12-28 VDC operating range (24 VDC typical)
  • DISPLAY: Dual-channel split-screen LED display (4 digit, 7-segment arrangement per channel) provides simultaneous display of one or two gases.
  • SIGNAL OUTPUT: 4-20 mA, linear (analog) and ModBus RTU (digital) RS485 digital communication with ModBus RTU software protocol system at 9600 baud. Three or four wire system capable of accommodating over 200 devices in bus configuration. Address selection through on-board 8-position dipswitch.
  • ALARM RELAYS: 3 alarm relays: Two user-programmable relays, SPST, N.O.; plus one fault relay, SPST, N.C.
  • CONTACT CAPACITY: 5 Amps @ 30 VDC
  • TEMPERATURE. RANGE: -4oF to +122oF (-20oC to +50oC), typical
  • HUMIDITY RANGE: 15-90% RH (non-condensing), typical
  • APPROVALS: (Sensor-specific)       Consult factory for current approval status CSA: Class I, Div. 1, 2, Groups B, C, D; AEx d IIB NRTL/c: Class I, Div. 1, 2, Groups B, C, D; AEx d IIB CENELEC (ATEX): EEx d IIB + H2 T5 Australia: Ex d IIB + H2 T6 China: GB 3836.1-Ex d IIC T4; LEL version GB15322-94 Fire protection
 

Honeywell BW™ Solo

Serviceable Single-gas Detector

The next-generation single-gas detector that helps you reduce
cost, ensure compliance and know your workers are protected.
Honeywell BW™ Solo has everything you expect — plus additional
features to make your compliance easier and more cost-effective
than ever. All with a reliable life span, one-button operation
and small, lightweight profile.


SPECIFICATION :

  • SIZE: 2.7 x 2.6 x 1.4 in. / 7.0 x 6.7x 3.6 cm (1-Series sensor models)
    2.7 x 2.6 x 1.6 in. / 7.0 x 6.7x 4.1 cm (4-Series sensor models)
  • WEIGHT : 3.6 to 4.1 oz. / 103 to 116 g, depending on installed sensor
  • HUMIDITY : 0% - 95% RH (non-condensing)
  • INGRESS PROTECTION : IP66/68
  • ALARMS AND TYPE : Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, non-compliance
  • SELF-TEST : Sensor integrity, circuitry, battery and audible/visual alarms on activation;
    battery (continuous)
  • TYPICAL BATTERY LIFE : 12 months (6 months for 1-Series O2)
  • CONNECTED WORKER : Bluetooth™ Low Energy (BLE) – Ability to connect to Honeywell’s Safety Communicator App
  • CERTIFICATIONS AND APPROVALS : Class I, Division 1, Groups A, B, C, D T4
    Class I, Zone 0, AEx/Ex ia IIC T4 Ga -40°C≤ Tamb ≤ 60°C
    ATEX: Sira 18ATEX2243
    X 2460 g II 1G Ex ia IIC T4 Ga
    g I M1 Ex ia I Ma -40°C≤ Tamb ≤ 60°C
    IECEx: IECEx SIR 18.0058
    Ex ia IIC T4 Ga / Ex ia I Ma -40°C≤ Tamb ≤ 60°C
    FCC ID: SU3BWS1
    IC: 20969-BWS1
    RED: RE-D Directive 2014/53/EU
 

Honeywell BW™ Max XT II Multi-Gas Detector

Honeywell BW™ Max XT II is the smart, simple, economical
way to compliance. Workers feel safe and incidents are minimized
so everyone will be able to do more. That means savings realized
from business continuity and productivity. With the addition of
IntelliFlash™, this multi-gas detector offers continuous visual
confirmation of detector operation and compliance.
• Minimize costs and training with one-button operation
• More accurate sampling results with SmartSample pump technology
• Compact, comfortable and field tough


SPECIFICATION :

  • SIZE: 5.1 x 2.8 x 2.0 in. / 13.1 x 7.0 x 5.2 cm
  • WEIGHT : 11.5 oz. / 328 g
  • OPERATING TEMPERATURE : -4 to 122ºF / -20 to 50ºC
  • HUMIDITY : 10 - 100% RH (non-condensing)
  • ALARMS AND TYPE : Visual, vibrating, audible (95 dB); Low, High, TWA, STEL, OL (over limit), Low Battery, Pump
  • SELF-TEST : Audible/visual alarms on activation, sensors,
    battery, pump and circuitry (continuous)
  • TYPICAL BATTERY LIFE : 13 hours @ 32ºF / 0ºC, 8 hours @ -4ºF / -20ºC, Recharges in 6 hours
  • PUMP DRAW : Sample from up to 75 ft. / 23 m
    Note: Do not attempt to calibrate a Honeywell BW™ Max XT with tubing longer than the standard calibration tubing supplied with the detector
  • CERTIFICATIONS AND APPROVALS : Class I, Div. 1, Gr. A, B, C, D
    IECEx: Ga Ex ia IIC T4
    ATEX: X g II 1 G Ga Ex ia IIC T4
    N : Br Ex ia IIC T4